A furnace that blows cold air is usually shutting its burners off after a few seconds because of a dirty flame sensor, a failing igniter, or an overheating limit switch caused by restricted airflow. Make sure the thermostat fan is set to Auto, not On, and replace a dirty filter. If air is still cold, call (208) 683-7054.
Check this first
- Thermostat fan setting: On circulates unheated air between cycles.
- Filter: replace if grey or clogged.
- Supply registers open and not blocked by furniture.
Causes behind cold air
- Coated flame sensor: burners light, then shut off within seconds.
- Cracked igniter: burners never light.
- Tripped high-limit switch: burners stop while the blower keeps running.
- Duct leaks in an attic or crawl space cooling the air before it reaches rooms.
- Weak blower capacitor reducing airflow.
What we check
- Thermostat settings and heat call.
- Flame sensor and igniter.
- Limit switch and rollout sensor.
- Blower amperage and filter.
- Duct connections for obvious leaks.
Boise's dry winters and cold nights keep furnaces running for long stretches. Source: [NWS Boise climate summary](https://www.weather.gov/boi/climatesummary). If heat fails completely, see furnace not heating.
Technician insight
In Boise 83709 the dry air and fine dust from nearby foothills clog filters and sensors quicker than most homeowners expect, especially in homes with original ductwork from the 1980s and 1990s around Bird Street and the airport corridor.
Cold Air From Registers In South Boise Home
A 83709 homeowner called after the furnace ran continuously yet supplied only cool air. We found a coated flame sensor and restricted filter on a 22-year-old unit. After cleaning the sensor and installing a new filter the furnace resumed normal heating cycles with proper temperature rise at the vents.
Furnace Blowing Cold Air Services We Offer
✓Flame Sensor Cleaning or Replacement
Cleans or replaces a sensor that shuts the gas valve and leaves only cool air.
✓Ignition System Repair
Repairs or replaces igniters that stop burners lighting.
✓Blower and Capacitor Service
Tests motors and capacitors that cut airflow.
✓Filter and Duct Inspection
Replaces clogged filters and checks duct leaks that cool the air.
✓Thermostat Check
Verifies the heat call and fan setting.
Furnace Blowing Cold Air Cost in Boise, ID
| Service | Typical Range | What Affects It |
|---|---|---|
| Diagnostic Visit | $95–$175 | Covers travel within 83709 and full system check; applied to repairs |
| Flame Sensor Service | $120–$220 | Includes cleaning or replacement plus retest |
| Igniter Replacement | $180–$320 | Part and labor; varies by furnace model age |
| Blower Capacitor Swap | $140–$260 | Common fix for weak airflow in older units |
Ranges are typical for Boise, ID and confirmed with an exact written quote before any work starts.
How it works
- 1
System check
Run the furnace through a cycle while checking thermostat settings and listening for short cycling.
- 2
Component diagnostics
Test the flame sensor, igniter, gas pressure and limit switch.
- 3
Targeted repair
Clean sensors, replace failed parts or seal duct joints based on findings.
- 4
Verification
Restart and confirm temperature rise at several registers.
Pricing
The diagnosis comes first; the repair price is explained before work starts.