A furnace that tries to start three times and locks out usually has a cracked hot-surface igniter, a coated flame sensor or a failing gas valve. Most modern furnaces use a hot-surface igniter and a flame sensor, so this page covers that system. Older standing-pilot units are covered under pilot light problems. Call (208) 683-7054 if your furnace will not light.
Ignition symptoms
- No glow from the igniter: igniter or control board.
- Glows, burners light, then shut off in seconds: flame sensor.
- Repeated retries then lockout: sensor, gas supply or pressure switch.
- Clicking with no flame: valve or igniter.
What we check first
- Error code on the control board LED.
- Igniter resistance and visible cracks.
- Flame sensor microamp reading.
- Gas valve operation and manifold pressure.
- Venting and pressure switch.
Why not just reset it
Repeated resets can let unburned gas build up before the burners light. Have the ignition chain tested before cycling the power again. Cold nights and long run times shorten igniter life. Source: [NWS Boise climate summary](https://www.weather.gov/boi/climatesummary). For standing pilots see pilot light problems.
Technician insight
In Boise 83709, the thing that catches most people out with Furnace Ignition Repair is how quickly dust from the dry summer months coats flame sensors in homes built on the west side near the airport, causing lockouts the first week temperatures drop below 25 degrees.
West Boise ranch home short cycling
A 1994 furnace in a single-story home off Maple Grove stopped firing after the first hard freeze. Testing showed the hot surface igniter had high resistance and the flame sensor read below 1 microamp. The igniter and sensor were replaced, wiring was secured, and the furnace completed five consecutive cycles without lockout.
Furnace Ignition Repair Services We Offer
✓Hot-surface Igniter Replacement
Replaces cracked or weak igniters that prevent burner ignition.
✓Flame Sensor Cleaning
Cleans or replaces oxidized sensors that close the gas valve.
✓Gas Valve Testing
Checks valve operation and manifold pressure.
✓Control Board Diagnostics
Reads codes and tests the ignition sequence.
Furnace Ignition Repair Cost in Boise, ID
| Service | Typical Range | What Affects It |
|---|---|---|
| Hot Surface Igniter Replacement | $225–$350 | Price varies by furnace brand and whether access requires panel removal in tight utility rooms. |
| Flame Sensor Service | $150–$275 | Includes cleaning; replacement adds cost if sensor is pitted. |
| Ignition Module Replacement | $300–$550 | Higher end when board is discontinued and requires wiring adaptation. |
Ranges are typical for Boise, ID and confirmed with an exact written quote before any work starts.
How it works
- 1
Read the code
Check the board LED and note how many ignition attempts occur.
- 2
Test the igniter and sensor
Measure igniter resistance and flame sensor signal.
- 3
Check gas and venting
Verify gas pressure, valve operation and pressure switch.
- 4
Repair and verify
Replace the failed part and run several full cycles.
Pricing
Parts vary by furnace model; the price is explained after the ignition diagnosis and before work starts.